Model | MP-2 | ||
Sensor Type | Flat Surfaced Semiconductor | ||
Standard Encapsulation | Metal Cap | ||
Target Gas | C3H8, smoke | ||
Detection range | 200~10000ppm C3H8 | ||
Standard Circuit Conditions | Loop Voltage | Vc | ≤10V DC |
Heater Voltage | VH | 5V±0.1V AC or DC | |
Load Resistance | RL | Adjustable | |
Sensor character under standard test conditions | Heater Resistance | RH | 105Ω±10Ω (room tem.) |
Heater consumption | PH | ≤240mW | |
Sensitivity | S | Ro(in air)/Rs( in 2000ppm C3H8)≥3 | |
Output voltage | Vs | 2.5V~4.0V (in 2000ppm C3H8) | |
Concentration Slope | α | ≤0.6(R3000ppm/R500ppm C3H8) | |
Environment Conditions | Operation Temp. | Tao | -10℃~50℃ |
Storage Temp. | Tas | -20℃~70℃ | |
Relative Humidity | RH | Less than 95%RH | |
O2 concentration | O2 | 21%±1%(can’t less than 18%) O2 concentration effects sensor’s performance. | |
Preheat time | Not less than 48 hours |
After sale instructions